Modern Manufacturing Engineering ›› 2018, Vol. 457 ›› Issue (10): 144-148.doi: 10.16731/j.cnki.1671-3133.2018.10.024

Previous Articles     Next Articles

The fault diagnosis method of abnormal combustion engine valve clearance based on Teager energy operator

Zhang Xiaofan1, Wu Yalong2, Yao Ziyun1, Mao Zhiwei1, Jiang Zhinong1   

  1. 1 Beijing Key Laboratory of Health Monitoring Control and Fault Self-Recovery for High-end Machinery,Beijing University of Chemical Technology,Beijing 100029,China;
    2 Henan Diesel Engine Industry Co.Ltd.,Luoyang 471039,Henan,China
  • Received:2017-05-11 Published:2019-01-07

Abstract: In order to study the abnormal valve clearance fault diagnosis method,by the simulation and experiment study,the core components of the gas distribution has been modeled in ADAMS,and the dynamic behaviors with different valve clearance has been simulated,in order to study the fault mechanism and the sensitive feature.Based on Teager energy operator,the accurate method to extract the sensitive feature from the actual vibration signal has been explored.This fault has been simulated in the TBD234 combustion engine test stand,vibration signal acquired.With the increasing of clearance,the phase of valve opening holds off,the phase of shutting is ahead of time,and the amplitude increases,which verifies the sensitivity of fault feature and effectiveness of the diagnosis method.

Key words: fault diagnosis, abnormal valve clearance, impact extraction, combustion engine